Hitachii 42pD3200 plasma tv buzz problem

9 posts / 0 new
Last post
nocomp
Hitachii 42pD3200 plasma tv buzz problem

Hi

 My tv has developed a mains sounding buzz when power turned on - it stays until TV turned off. If I mute the speakers the buzz is still there, but does not appear to be coming from the mains area

 Any ideas on how to diagnose?

 thanks

  nocomp

Larry Dillon
Need a little more

Need a little more information please.  Is it comming from the speakers them self?  From the back of the set.  When you say mains, are you talking about the suround sound system, or the tV set speakers?  Have you tryed to turn off the suround sound system if you have one and leave the TV on?

nocomp
Hi

Hi

The sound is comming from the rear of the TV and remains when the spears are muted - the sound decreases if the TV is left on for a peroid of 3-4 hours but returns if you tun the tv off andd on

thanks

nocomp

Larry Dillon
Well it could be a

Well it could be a transformer, coil or deflection yolk ringing.  Is it high pitched or a low sound?

nocomp
Hi

Hi

 Thanks for your advice - got an engineer in - it is a faulty mains transformer (there are three in the TV) - its being replaced this week

 

 

nocomp

Larry Dillon
Please let us have the scoop

Please let us have the scoop on the repir please?

nocomp
they have taken it away for

they have taken it away for repair - will update when (if) it returns

ovadoggvo
This is a common problem on

This is a common problem on these plasma TV's. The problem resides in the high voltage boards known as the X and Y Sustain boards.. You can purchase them here for a very reasonable price:
http://www.discount-merchant.com/Y-SUSTAIN-FOR-42-PLASMA-TV-PN-6871QYH03...

The above link is to a Y-SUS board. The X-Sus board is often the 2nd cause of failure and can be found here:
http://www.discount-merchant.com/X-SUSTAIN-6871QZH041B-6870QZE017D-6871Q...

To test which board is failing, you need to check voltage input to the YSUS board first... Input should be 120V from Power supply, output should be above 250V.. Do this test with XSUS disconnected. IF 250+V exists, then XSUS is damaged. If not, then the YSUS is the faulty part.

Larry Dillon
it is great that you wish tom

it is great that you wish tom help other folks as I do but both of those links you left are dead links, please do not leave dead links!!!!!!!!
Larry D

 